Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/75583
Título: Validation of vertebral metrics: a mechanical instrument to evaluate posture of the spinal column
Autor: Quaresma, C.
João, F.
Fonseca, M.
Secca, M. Forjaz
Veloso, A.
O'Neil, J. Goyri
Branco, J.
Palavras-chave: Biomechanics
Instrumentation
Spine
Validation
Biomedical Engineering
Bioengineering
Data: 1-Dez-2009
Editora: Springer Verlag
Citação: Quaresma, C., João, F., Fonseca, M., Secca, M. F., Veloso, A., O'Neil, J. G., & Branco, J. (2009). Validation of vertebral metrics: a mechanical instrument to evaluate posture of the spinal column. In O. Dössel, & W. C. Schlegel (Eds.), World Congress on Medical Physics and Biomedical Engineering: Diagnostic and Therapeutic Instrumentation, Clinical Engineering (pp. 711-713). (IFMBE Proceedings; Vol. 25, No. 7). Springer Verlag. https://doi.org/10.1007/978-3-642-03885-3-197
Resumo: The purpose of this study is to verify the validity of the instrument Vertebral Metrics, designed to identify X, Y, and Z positions of - each vertebral apophyses, by comparing the results obtained from this instrument with those from an optoelectronic system of Stereophogrammetry, composed of 10 infrared cameras with a sampling frequency of 200 Hz. Methodology: The sample consisted of 11 women aged between 14 and 39 years. After marking the various points in the spinal column, from the 1st cervical vertebra to the 1st sacral vertebra, each woman's backbone was first measured with Vertebral Metrics and then measured with the optoelectronics system. Later, the results obtained with the two instruments were compared. Results: For our analysis we used an ANOVA model with 3 factors (Instrument, Subject and vertebrates) for the intervertebral distance. Conclusion: The Vertebral Metrics proved to be a reliable and valid apparatus when compared with the optoelectronics system.
Peer review: yes
URI: http://www.scopus.com/inward/record.url?scp=77949799190&partnerID=8YFLogxK
DOI: https://doi.org/10.1007/978-3-642-03885-3-197
ISBN: 978-3-642-03884-6
978-3-642-03885-3
ISSN: 1680-0737
Aparece nas colecções:FCT: DF - Documentos de conferências internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Quaresma2009_Chapter_ValidationOfVertebralMetricsAM.pdf179,43 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.