Logo do repositório
 
Publicação

Validation of vertebral metrics: a mechanical instrument to evaluate posture of the spinal column

dc.contributor.authorQuaresma, C.
dc.contributor.authorJoão, F.
dc.contributor.authorFonseca, M.
dc.contributor.authorSecca, M. Forjaz
dc.contributor.authorVeloso, A.
dc.contributor.authorO'Neil, J. Goyri
dc.contributor.authorBranco, J.
dc.contributor.institutionDF – Departamento de Física
dc.contributor.institutionCeFITec – Centro de Física e Investigação Tecnológica
dc.contributor.institutionCMA - Centro de Matemática e Aplicações
dc.contributor.institutionDM - Departamento de Matemática
dc.contributor.institutionNOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)
dc.coverage.spatialBerlin, Heidelberg
dc.date.accessioned2019-07-15T22:54:18Z
dc.date.available2019-07-15T22:54:18Z
dc.date.issued2009-12-01
dc.description.abstractThe purpose of this study is to verify the validity of the instrument Vertebral Metrics, designed to identify X, Y, and Z positions of - each vertebral apophyses, by comparing the results obtained from this instrument with those from an optoelectronic system of Stereophogrammetry, composed of 10 infrared cameras with a sampling frequency of 200 Hz. Methodology: The sample consisted of 11 women aged between 14 and 39 years. After marking the various points in the spinal column, from the 1st cervical vertebra to the 1st sacral vertebra, each woman's backbone was first measured with Vertebral Metrics and then measured with the optoelectronics system. Later, the results obtained with the two instruments were compared. Results: For our analysis we used an ANOVA model with 3 factors (Instrument, Subject and vertebrates) for the intervertebral distance. Conclusion: The Vertebral Metrics proved to be a reliable and valid apparatus when compared with the optoelectronics system.en
dc.description.versionpublished
dc.format.extent3
dc.format.extent183736
dc.identifier.doi10.1007/978-3-642-03885-3-197
dc.identifier.isbn978-3-642-03884-6
dc.identifier.isbn978-3-642-03885-3
dc.identifier.issn1680-0737
dc.identifier.otherPURE: 6339920
dc.identifier.otherPURE UUID: 173e3180-71b1-49d2-8beb-8dc8a79347f2
dc.identifier.otherScopus: 77949799190
dc.identifier.otherORCID: /0000-0001-9978-261X/work/100618055
dc.identifier.urihttp://www.scopus.com/inward/record.url?scp=77949799190&partnerID=8YFLogxK
dc.identifier.urlhttps://www.scopus.com/pages/publications/77949799190
dc.language.isoeng
dc.peerreviewedyes
dc.publisherSpringer Verlag
dc.subjectBiomechanics
dc.subjectInstrumentation
dc.subjectSpine
dc.subjectValidation
dc.subjectBiomedical Engineering
dc.subjectBioengineering
dc.titleValidation of vertebral metrics: a mechanical instrument to evaluate posture of the spinal columnen
dc.typeconference object
degois.publication.firstPage711
degois.publication.lastPage713
degois.publication.titleWorld Congress on Medical Physics and Biomedical Engineering: Diagnostic and Therapeutic Instrumentation, Clinical Engineering
degois.publication.titleWorld Congress on Medical Physics and Biomedical Engineering: Diagnostic and Therapeutic Instrumentation, Clinical Engineering
dspace.entity.typePublication
rcaap.rightsrestrictedAccess

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
Quaresma2009_Chapter_ValidationOfVertebralMetricsAM.pdf
Tamanho:
179.43 KB
Formato:
Adobe Portable Document Format