dc.description.abstractINTRODUCTION Minimal invasive surgical treatment of female stress urinary incontinence with suburethral transobturator tapes is completely accepted nowadays. The purpose of this study is to evaluate the efficacy and security of these suburethral tapes, comparing the outside-in to the inside-out approach. MATERIAL AND METHODS We performed a retrospective study of 298 patients with stress urinary incontinence diagnosis that were submitted to transobturator surgery between 2003 and 2006. From these patients 113 women underwent outside-in approach and 185 patients had inside-out approach. RESULTS The mean-age of the patients was 57.2 +/- 10.3 years-old and 69.1% were in the post-menopausal period. Mean parity was 2.2 +/- 1.1. The outside-in approach was performed more frequently in association with other(s) pelvic floor surgery(ies) (83.2% versus 37.8% for the inside-out technique). The mean follow-up duration was of 14.35 +/- 13.75 months in those patients who had a transobturator outside-in technique and of 11.79 +/- 10.39 months in the inside-out group. In respect to the efficacy, results were identical in the two groups with cure and cure or improvement rates respectively of 76.9% and 92.9% in the outside-in group and of 82.7% and 93.5% in the inside-out group (differences not significative). Regarding mean procedure duration, when it was performed isolated, we had a significant lower duration in patients submitted to inside-out technique (14.77 +/- 5.37 minutes versus 21.21 +/- 7.48 minutes, p < 0.05). The post-operative rates of de novo urge incontinence and mesh erosions were identical in the two groups, however microporous tapes had more erosions than macroporous ones (p < 0.05). DISCUSSION AND CONCLUSIONS The transobturator suburethral tapes are effective and safe for the stress urinary incontinence treatment. We had elevated cure and improvement rates with no significant differences in regard to performed procedure. The inside-out technique is significantly associated to a lower operative duration.en
dc.description.versionpublishersversion
dc.description.versionpublished
dc.format.extent8
dc.format.extent239702
dc.identifier.issn1646-0758
dc.identifier.otherPURE: 503861
dc.identifier.otherPURE UUID: 001def73-c0ec-45e4-a037-e0d9216c5547
dc.identifier.otherresearchoutputwizard: 14755
dc.identifier.otherPubMed: 20687986
dc.identifier.otherWOS: 000282525800004
dc.identifier.otherScopus: 78349295711
dc.identifier.urihttp://hdl.handle.net/10362/21849
dc.language.isopor
dc.peerreviewedyes
dc.titleFitas suburetrais transobturadoras na incontinência urinária de esforço feminina: resultados a médio prazopt
dc.title.alternativeTransobturator tapes for stress urinary incontinence treatment: middle-term resultsen
dc.typejournal article
degois.publication.firstPage589
degois.publication.issue4
degois.publication.lastPage96
degois.publication.titleActa Médica Portuguesa
degois.publication.volume23
dspace.entity.typePublication
rcaap.rightsopenAccess

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
589-596.pdf
Tamanho:
234.08 KB
Formato:
Adobe Portable Document Format