Logo do repositório
 
Publicação

Controlo da ventilação.

dc.contributor.authorBárbara, C.
dc.contributor.authorCarmo, M. M.
dc.contributor.authorRendas, A. B.
dc.contributor.authorRendas, António
dc.contributor.authorAvila, R.
dc.contributor.institutionNOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)
dc.contributor.pblBiblioteca Nacional de Portugal, Centro de Estudos Históricos, CELOM
dc.date.accessioned2018-06-04T22:04:38Z
dc.date.available2018-06-04T22:04:38Z
dc.date.issued1995-07-01
dc.description.abstractThe control system of breathing can be considered as a closed loop system, consisting of two subsystems: the controlling system and the controlled system. Both systems are defined by their input-output relationships. The controlling system is defined by the Respiratory Centers that are responsible for two separate, but overlapping, patterns: the automatic control pattern and the behavioral or voluntary control. In the controlling system the input is the blood gas value and the output is some parameters of ventilation. The controlled system is characterized by an input of ventilation and an output of blood gas values. In this closed loop system breathing is normally regulated by two anatomically distinct but functionally integrated elements, referred to as the metabolic and behavioral respiratory control systems. The metabolic control is concerned with blood gas homeostasis and the voluntary control relates with activities such as phonation and singing that use the ventilatory apparatus for purposes other than gas exchange.en
dc.description.versionpublishersversion
dc.description.versionpublished
dc.format.extent8
dc.format.extent790183
dc.identifier.issn0870-399X
dc.identifier.otherPURE: 4306488
dc.identifier.otherPURE UUID: 5ea9dda8-8c71-49a9-ad91-d9309f846a6b
dc.identifier.otherScopus: 0029336981
dc.identifier.otherPubMed: 7484257
dc.identifier.urihttp://www.scopus.com/inward/record.url?scp=0029336981&partnerID=8YFLogxK
dc.identifier.urihttps://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/2725/2115
dc.identifier.urlhttps://www.scopus.com/pages/publications/0029336981
dc.identifier.urlhttps://www.actamedicaportuguesa.com/revista/index.php/amp/article/view/2725/2115
dc.language.isopor
dc.peerreviewedyes
dc.subjectGeneral Medicine
dc.titleControlo da ventilação.pt
dc.title.alternativeControl of breathingen
dc.typereview
degois.publication.firstPage433
degois.publication.issue7-8
degois.publication.lastPage440
degois.publication.titleActa Médica Portuguesa
degois.publication.volume8
dspace.entity.typePublication
person.familyNameBensabat Rendas
person.givenNameAntónio Manuel
person.identifier.orcid0000-0001-5173-4256
rcaap.rightsopenAccess
relation.isAuthorOfPublicationea6542be-17dc-4ddb-9603-e6a32a3f5245
relation.isAuthorOfPublication.latestForDiscoveryea6542be-17dc-4ddb-9603-e6a32a3f5245

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
2725_3650_1_PB.pdf
Tamanho:
771.66 KB
Formato:
Adobe Portable Document Format