Publicação
Point-of-care testing of nitrite in oral medicine
| dc.contributor.author | Gaspar, Sara Rodrigues | |
| dc.contributor.author | Proença, Luís | |
| dc.contributor.author | Alves, Ricardo | |
| dc.contributor.author | Almeida, Maria Gabriela | |
| dc.contributor.institution | DQ - Departamento de Química | |
| dc.contributor.institution | UCIBIO - Applied Molecular Biosciences Unit | |
| dc.contributor.pbl | Elsevier BV | |
| dc.date.accessioned | 2025-09-05T22:31:09Z | |
| dc.date.available | 2025-09-05T22:31:09Z | |
| dc.date.issued | 2025-08 | |
| dc.description | Funding Information: This work is financed by national funds through the FCT – Foundation for Science and Technology, I.P., under the projects UIDB/04585/2020 (Research Center - CiiEM), UIDP/04378/2020 and UIDB/04378/2020 (Research Unit on Applied Molecular Biosciences - UCIBIO), and LA/P/0140/2020 (Associate Laboratory Institute for Health and Bioeconomy - i4HB), and for the research project 2022.04940.PTDC. The authors acknowledge Nuno Costa from Laboratório de Análises/REQUIMTE/LAQV at NOVA FCT, Portugal, for the acquisition of the ion chromatography data. Publisher Copyright: © 2025 The Authors | |
| dc.description.abstract | Periodontal disease (PD) is a chronic inflammatory condition triggered by bacterial biofilms and progresses through two main stages: gingivitis and periodontitis. The existing diagnostic methods remain time-consuming and require clinical expertise. Salivary nitrite, a stable end-product of nitric oxide produced during inflammation, has emerged as a promising biomarker for PD. However, its reliable quantification in saliva typically relies on laboratory-based assays that are unsuited to clinical workflows. This study aimed to test and validate a new nitrite point-of-care test (POCT) for oral medicine. Building on previous research, we developed a biosensing platform based on screen-printed carbon electrodes modified with a selective enzyme, the cytochrome c nitrite reductase. To adapt bioelectrodes for salivary analysis, they were further modified with a poly(vinyl) alcohol coating and a biochemical oxygen scavenger system (ascorbate oxidase and ascorbate). The nitrite biosensor achieved a suitable linear range of 5–300 μM, with a sensitivity of 0.015 μM−1, validated against the gold-standard Griess method. Unlike the Griess reaction, the biosensor was unaffected by sample turbidity, rendering centrifugation unnecessary. Additionally, we observed that sample freezing altered nitrite concentrations, increasing levels in non-centrifuged samples, while decreasing them in previously clarified samples. These findings highlight the need for real-time analysis and call into question the reliability of previously published data that overlooked these variables. Therefore, our results demonstrate the potential of the nitrite biosensor as a novel salivary POCT and emphasize the critical need for standardized sample-handling protocols. | en |
| dc.description.version | publishersversion | |
| dc.description.version | published | |
| dc.format.extent | 10 | |
| dc.format.extent | 4871062 | |
| dc.identifier.doi | 10.1016/j.sbsr.2025.100860 | |
| dc.identifier.issn | 2214-1804 | |
| dc.identifier.other | PURE: 128750520 | |
| dc.identifier.other | PURE UUID: 04b93e0e-3cc5-45ef-b35b-02832785287c | |
| dc.identifier.other | Scopus: 105012628995 | |
| dc.identifier.uri | http://hdl.handle.net/10362/187605 | |
| dc.identifier.url | https://www.scopus.com/pages/publications/105012628995 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.relation | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04585%2F2020/PT | |
| dc.relation | Egas Moniz Interdisciplinary Research Center | |
| dc.relation | Applied Molecular Biosciences Unit | |
| dc.relation | Applied Molecular Biosciences Unit | |
| dc.relation | info:eu-repo/grantAgreement/FCT/Concurso para Atribuição do Estatuto e Financiamento de Laboratórios Associados (LA)/LA%2FP%2F0140%2F2020/PT | |
| dc.relation | info:eu-repo/grantAgreement/FCT/3599-PPCDT/2022.04940.PTDC/PT | |
| dc.subject | Biosensors | |
| dc.subject | Nitrite | |
| dc.subject | Periodontal disease | |
| dc.subject | Point-of-care test | |
| dc.subject | Saliva | |
| dc.subject | Biotechnology | |
| dc.subject | Electronic, Optical and Magnetic Materials | |
| dc.subject | Analytical Chemistry | |
| dc.subject | Signal Processing | |
| dc.subject | Electrical and Electronic Engineering | |
| dc.subject | SDG 3 - Good Health and Well-being | |
| dc.title | Point-of-care testing of nitrite in oral medicine | en |
| dc.title.subtitle | Application and validation of an enzymatic biosensor in human saliva | en |
| dc.type | journal article | |
| degois.publication.firstPage | 1 | |
| degois.publication.lastPage | 10 | |
| degois.publication.title | Sensing and Bio-Sensing Research | |
| degois.publication.volume | 49 | |
| dspace.entity.type | Publication | |
| oaire.awardNumber | UIDB/04585/2020 | |
| oaire.awardNumber | UIDP/04378/2020 | |
| oaire.awardNumber | UIDB/04378/2020 | |
| oaire.awardNumber | LA/P/0140/2020 | |
| oaire.awardNumber | 2022.04940.PTDC | |
| oaire.awardTitle | Egas Moniz Interdisciplinary Research Center | |
| oaire.awardTitle | Applied Molecular Biosciences Unit | |
| oaire.awardTitle | Applied Molecular Biosciences Unit | |
| oaire.awardURI | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04585%2F2020/PT | |
| oaire.awardURI | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDP%2F04378%2F2020/PT | |
| oaire.awardURI | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04378%2F2020/PT | |
| oaire.awardURI | info:eu-repo/grantAgreement/FCT/Concurso para Atribuição do Estatuto e Financiamento de Laboratórios Associados (LA)/LA%2FP%2F0140%2F2020/PT | |
| oaire.awardURI | info:eu-repo/grantAgreement/FCT/3599-PPCDT/2022.04940.PTDC/PT | |
| oaire.fundingStream | 6817 - DCRRNI ID | |
| oaire.fundingStream | 6817 - DCRRNI ID | |
| oaire.fundingStream | 6817 - DCRRNI ID | |
| oaire.fundingStream | Concurso para Atribuição do Estatuto e Financiamento de Laboratórios Associados (LA) | |
| oaire.fundingStream | 3599-PPCDT | |
| project.funder.identifier | http://doi.org/10.13039/501100001871 | |
| project.funder.identifier | http://doi.org/10.13039/501100001871 | |
| project.funder.identifier | http://doi.org/10.13039/501100001871 | |
| project.funder.identifier | http://doi.org/10.13039/501100001871 | |
| project.funder.identifier | http://doi.org/10.13039/501100001871 | |
| project.funder.name | Fundação para a Ciência e a Tecnologia | |
| project.funder.name | Fundação para a Ciência e a Tecnologia | |
| project.funder.name | Fundação para a Ciência e a Tecnologia | |
| project.funder.name | Fundação para a Ciência e a Tecnologia | |
| project.funder.name | Fundação para a Ciência e a Tecnologia | |
| rcaap.rights | openAccess | |
| relation.isProjectOfPublication | 29698a2e-5c49-4923-aab9-3ffeee572562 | |
| relation.isProjectOfPublication | 38373452-5c9c-4724-8def-f03314ecce0e | |
| relation.isProjectOfPublication | e07cf232-4705-4b5b-b2c4-af8f25311076 | |
| relation.isProjectOfPublication | ecd6da06-821d-4fff-933b-319b334dc19a | |
| relation.isProjectOfPublication | b7b99f6d-6662-4823-b1a2-cfc58ed4e571 | |
| relation.isProjectOfPublication.latestForDiscovery | ecd6da06-821d-4fff-933b-319b334dc19a |
Ficheiros
Principais
1 - 1 de 1
A carregar...
- Nome:
- Gaspar_S._R._et_al._2025_..pdf
- Tamanho:
- 4.65 MB
- Formato:
- Adobe Portable Document Format
