Comparison of three assays for total and free PSA using hybritech and WHO calibrations

dc.contributor.authorGarrido, Manuel M.
dc.contributor.authorMarta, Jose C.
dc.contributor.authorRibeiro, Ruy M.
dc.contributor.authorPinheiro, Luis C.
dc.contributor.authorHoldenrieder, Stefan
dc.contributor.authorGuimaraes, Joao T.
dc.contributor.institutionNOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)
dc.contributor.pblInternational Institute of Anticancer Research
dc.date.accessioned2023-01-12T22:17:21Z
dc.date.available2023-01-12T22:17:21Z
dc.date.issued2021-12
dc.descriptionPublisher Copyright: © 2021 International Institute of Anticancer Research. All rights reserved.
dc.description.abstractBackground/Aim: Lack of interchangeability between prostate-specific antigen (PSA) assays could have a clinical impact. We compared PSA assays from different manufacturers and calibrations. Patients and Methods: A total of 233 men who underwent prostate biopsy (PSA: 2-10 ng/ml; Beckman Coulter Access® Hybritech® as reference) were enrolled. Total (tPSA) and free PSA (fPSA) were also measured using the Roche cobas® and the Abbott Architect® methods. Results: Roche tPSA values were ≈ 1% higher than Beckman, while Abbott values were ~5% lower. Roche had the highest diagnostic sensitivity (92%) compared to Beckman Coulter (87%) and Abbott (85%). Roche fPSA was ≈3% lower and Abbott ≈17% higher than that of Beckman. For the percentage of fPSA, Roche had the highest sensitivity (98%). Conclusion: Roche cobas® and Beckman Coulter Access® Hybritech® tPSA were almost interchangeable. While the agreement was acceptable for tPSA, this did not happen with fPSA and greater efforts for harmonization are required.en
dc.description.versionpublishersversion
dc.description.versionpublished
dc.format.extent9
dc.format.extent1508550
dc.identifier.doi10.21873/invivo.12643
dc.identifier.issn0258-851X
dc.identifier.otherPURE: 35103969
dc.identifier.otherPURE UUID: befd14c0-c1a4-4b7d-82f1-ea96f1d1b1f4
dc.identifier.otherScopus: 85119267799
dc.identifier.otherWOS: 000711693300028
dc.identifier.urihttp://hdl.handle.net/10362/147444
dc.identifier.urlhttps://www.scopus.com/pages/publications/85119267799
dc.language.isoeng
dc.peerreviewedyes
dc.subjectFree PSA
dc.subjectHybritech calibration
dc.subjectMethod comparison
dc.subjectProstate cancer
dc.subjectTotal PSA
dc.subjectWHO calibration
dc.subjectGeneral Biochemistry,Genetics and Molecular Biology
dc.subjectPharmacology
dc.subjectSDG 3 - Good Health and Well-being
dc.titleComparison of three assays for total and free PSA using hybritech and WHO calibrationsen
dc.typejournal article
degois.publication.firstPage3431
degois.publication.issue6
degois.publication.lastPage3439