Please use this identifier to cite or link to this item: http://hdl.handle.net/10362/164333
Title: Seismic Behavior of Slab-Column Connections Using High Performance Fiber Reinforced Concretes
Author: Ramos, António
Isufi, Brisid
Marreiros, Rui
Keywords: flat plate
flat slab
high performance fiber reinforced concrete
high strength concrete
punching shear
seismic loading
Civil and Structural Engineering
Building and Construction
Materials Science(all)
Issue Date: 1-Apr-2023
Publisher: American Concrete Institute
Citation: Ramos, A., Isufi, B., & Marreiros, R. (2023). Seismic Behavior of Slab-Column Connections Using High Performance Fiber Reinforced Concretes. In A. Genikomsou, T. Hrynyk, & E. Lantsoght (Eds.), Punching Shear of Concrete Slabs: Insights from New Materials, Tests, and Analysis Methods (pp. 123-138). (American Concrete Institute, ACI Special Publication; Vol. SP-357). American Concrete Institute. https://doi.org/10.14359/51738763
Abstract: Significant research efforts have been devoted to achieving high performance of slab – column connections subjected to lateral loading. Solutions such as using stirrups and headed studs have been shown to work well. With the development of concrete materials with enhanced properties, new possibilities have arisen to employ solutions that are easy to apply and cause less congestion of reinforcement. A total of nine tests on flat slab specimens subjected to combined gravity and lateral loading are discussed, including two new specimens with High Performance Fiber Reinforced Concrete (HPFRC) over a limited region near the column. The main experimental variables were the flexural reinforcement ratio and the punching shear improvement method: none, headed studs, High Strength Concrete (HSC) or HPFRC. It is shown that excellent behavior is achieved with a relatively small amount of HPFRC, extended up to 1.5 times the effective depth of the slab from the face of the column. Punching was completely avoided until the end of the loading protocol (6% drift) for the specimens with HPFRC, whereas reference specimens without punching shear reinforcement failed at 1% drift and specimens with HSC reached 3% drifts. Additionally, the use of HPFRC led to an increased unbalanced moment transfer capacity and lateral stiffness, though this effect was more pronounced for specimens with lower flexural reinforcement ratio.
Description: This work is also part of the research activity carried out at Civil Engineering Research and Innovation for Sustainability (CERIS). Publisher Copyright: © 2023 American Concrete Institute. All rights reserved.
Peer review: yes
URI: http://hdl.handle.net/10362/164333
DOI: https://doi.org/10.14359/51738763
ISBN: 978-164195212-5
ISSN: 0193-2527
Appears in Collections:FCT: DEC - Documentos de conferências internacionais

Files in This Item:
File Description SizeFormat 
ACI_FCT_HPCfinal_dual_units.pdf1,12 MBAdobe PDFView/Open


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.