Please use this identifier to cite or link to this item: http://hdl.handle.net/10362/149579
Title: The impact of indoor air quality and contaminants on respiratory health of older people living in long-term care residences in Porto
Author: Mendes, Ana
Papoila, A.L.
Martins, Pedro Carreiro
Bonassi, Stefano
Caires, Iolanda
Palmeiro, Teresa
Aguiar, Lívia
Pereira, Cristiana
Neves, Paula
Mendes, Diana
Botelho, Amalia
Neuparth, N
Teixeira, João Paulo
Keywords: allergic rhinitis
indoor air quality
long-term care residences
older people
respiratory health
SDG 11 - Sustainable Cities and Communities
SDG 13 - Climate Action
Issue Date: Jan-2016
Abstract: BACKGROUND: persons who are 65 years or older often spend an important part of their lives indoors thus adverse indoor climate might influence their health status. OBJECTIVE: to evaluate the influence of indoor air quality and contaminants on older people's respiratory health. DESIGN: cross-sectional study. SETTING: 21 long-term care residences (LTC) in the city of Porto, Portugal. SUBJECTS: older people living in LTC with ≥65 years old. METHODS: the Portuguese version of BOLD questionnaire was administered by an interviewer to older residents able to participate (n = 143). Indoor air contaminants (IAC) were measured twice, during winter and summer in 135 areas. Mixed effects logistic regression models were used to study the association between the health questionnaire results and the monitored IAC, adjusted for age, smoking habits, gender and number of years living in the LTC. RESULTS: cough (23%) and sputum (12%) were the major respiratory symptoms, and allergic rhinitis (22%) the main self-reported illness. Overall particulate matter up to 2.5 micrometres in size median concentration was above the reference levels both in winter and summer seasons. Peak values of particulate matter up to 10 micrometres in size (PM10), total volatile organic compounds, carbon dioxide, bacteria and fungi exceeded the reference levels. Older people exposed to PM10 above the reference levels demonstrated higher odds of allergic rhinitis (OR = 2.9, 95% CI: 1.1-7.2). CONCLUSION: high levels of PM10 were associated with 3-fold odds of allergic rhinitis. No association was found between indoor air chemical and biological contaminants and respiratory symptoms.
Description: Funding This work was supported by GERIA Project PTDC/ SAU-SAP/116563/2010, a PhD Grant (SFRH/BD/72399/ 2010) from Foundation for Science and Technology (Fundação para a Ciência e Tecnologia - FCT) through Operational Competitiveness Programme (COMPETE) as part of the National Strategic Reference Framework and a grant funded by AIRC (Associazione Italiana per la Ricerca sul Cancro).
Peer review: yes
URI: http://hdl.handle.net/10362/149579
DOI: https://doi.org/10.1093/ageing/afv157
ISSN: 0002-0729
Appears in Collections:NMS: CEDOC - Artigos em revista internacional com arbitragem científica

Files in This Item:
File Description SizeFormat 
afv157.pdf167,9 kBAdobe PDFView/Open


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.