Utilize este identificador para referenciar este registo:
                
    
    http://hdl.handle.net/10362/60290| Título: | Does impedance matter when recording spikes with polytrodes? | 
| Autor: | Neto, Joana P. Baião, Pedro Lopes, Gonçalo Frazão, João Nogueira, Joana Fortunato, Elvira Barquinha, Pedro Kampff, Adam R.  | 
| Palavras-chave: | Coating Impedance Microelectrodes Noise Spikes Neuroscience(all)  | 
| Data: | 8-Out-2018 | 
| Citação: | Neto, J. P., Baião, P., Lopes, G., Frazão, J., Nogueira, J., Fortunato, E., Barquinha, P., & Kampff, A. R. (2018). Does impedance matter when recording spikes with polytrodes? Frontiers in Neuroscience, 12(OCT), Article 715. https://doi.org/10.3389/fnins.2018.00715 | 
| Resumo: | Extracellular microelectrodes have been widely used to measure brain activity, yet there are still basic questions about the requirements for a good extracellular microelectrode. One common source of confusion is how much an electrode's impedance affects the amplitude of extracellular spikes and background noise. Here we quantify the effect of an electrode's impedance on data quality in extracellular recordings, which is crucial for both the detection of spikes and their assignment to the correct neurons. This study employs commercial polytrodes containing 32 electrodes (177 μm2) arranged in a dense array. This allowed us to directly compare, side-by-side, the same extracellular signals measured by modified low impedance (∼100 kΩ) microelectrodes with unmodified high impedance (∼1 MΩ) microelectrodes. We begin with an evaluation of existing protocols to lower the impedance of the electrodes. The poly (3,4-ethylenedioxythiophene)-polystyrene sulfonate (PEDOT-PSS) electrodeposition protocol is a simple, stable, and reliable method for decreasing the impedance of a microelectrode up to 10-fold. We next record in vivo using polytrodes that are modified in a 'chess board' pattern, such that the signal of one neuron is detected by multiple coated and non-coated electrodes. The performance of the coated and non-coated electrodes is then compared on measures of background noise and amplitude of the detected action potentials. If the proper recording system is used, then the impedance of a microelectrode within the range of standard polytrodes (∼0.1 to 2 MΩ) does not greatly affect data quality and spike sorting. This study should encourage neuroscientists to stop worrying about one more unknown. | 
| Descrição: | This work was supported by funding from the European Union's Seventh Framework Programme (FP7/2007-2013) Grant Agreement 600925, the Bial Foundation Grant 190/12 and the FCT-MCTES Doctoral Grant SFRH/BD/76004/2011 (to JN). | 
| Peer review: | yes | 
| URI: | http://www.scopus.com/inward/record.url?scp=85055145075&partnerID=8YFLogxK | 
| DOI: | https://doi.org/10.3389/fnins.2018.00715 | 
| ISSN: | 1662-4548 | 
| Aparece nas colecções: | FCT: DCM - Artigos em revista internacional com arbitragem científica | 
Ficheiros deste registo:
| Ficheiro | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| fnins_12_00715.pdf | 2,32 MB | Adobe PDF | Ver/Abrir | 
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.











