Utilize este identificador para referenciar este registo:
http://hdl.handle.net/10362/58114
Registo completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.advisor | Fortunato, Elvira | - |
dc.contributor.advisor | Pereira, Luís | - |
dc.contributor.author | Fernandes, Alexandra Agostinho Gomes | - |
dc.date.accessioned | 2019-01-21T16:30:34Z | - |
dc.date.available | 2019-01-21T16:30:34Z | - |
dc.date.issued | 2018-12 | - |
dc.date.submitted | 2018 | - |
dc.identifier.uri | http://hdl.handle.net/10362/58114 | - |
dc.description.abstract | Cystic Fibrosis (CF) is an inherited disorder affecting more than 70000 people worldwide, especially Caucasian populations with a carrier prevalence of 1/3000. Currently, it has no cure but an early diagnosis remains a critical issue. Sweat chloride test has been the gold standard to diagnose CF since the affected present sweat chloride concentrations ≥ 60 mM. In this work, a planar electrochromic “point-of-care” device, based on tungsten trioxide nanoparticles produced by microwave assisted hydrothermal synthesis, was developed as a first approach for CF diagnostic testing especially in resource-limited environments. For electrodes patterning, a CO2 laser technology was used in a PET/ITO sheet. The device presents a design that allows the NaCl-based electrolyte deposition, used as artificial sweat, only on time of usage directly on the nanoparticles or in a paper pad. By applying an operating voltage of -3 V, the nanoparticles change their optical properties according to NaCl concentration, presenting a blue colouration with different intensities for different NaCl concentrations. The device was able to differentiate between a positive and negative diagnosis, with a colouration time of only 1 min, using an RGB analysis with a B/R ratio of 1.37±0.03 for 60 mM of NaCl, and a low power consumption. | pt_PT |
dc.language.iso | eng | pt_PT |
dc.rights | openAccess | pt_PT |
dc.subject | Cystic Fibrosis | pt_PT |
dc.subject | sodium sweat detection | pt_PT |
dc.subject | hydrothermal synthesis | pt_PT |
dc.subject | electrochromic device | pt_PT |
dc.subject | tungsten trioxide nanoparticles | pt_PT |
dc.subject | colourimetric detection | pt_PT |
dc.title | An electrochromic paper-based device as a diagnostic test for Cystic Fibrosis | pt_PT |
dc.type | masterThesis | pt_PT |
thesis.degree.name | Mestre em Engenharia de Micro e Nanotecnologias | pt_PT |
dc.subject.fos | Domínio/Área Científica::Engenharia e Tecnologia::Engenharia dos Materiais | pt_PT |
Aparece nas colecções: | FCT: DCM - Dissertações de Mestrado |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Fernandes_2018.pdf | 3,81 MB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.