Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/157010
Título: Data standards for transcatheter aortic valve implantation
Autor: Aktaa, Suleman
Batra, Gorav
James, Stefan K.
Blackman, Daniel J.
Ludman, Peter F.
Mamas, Mamas A.
Abdel-Wahab, Mohamed
Angelini, Gianni D.
Czerny, Martin
Delgado, Victoria
De Luca, Giuseppe
Agricola, Eustachio
Foldager, Dan
Hamm, Christian W.
Iung, Bernard
Mangner, Norman
Mehilli, Julinda
Murphy, Gavin J.
Mylotte, Darren
Parma, Radoslaw
Petronio, Anna Sonia
Popescu, Bodgan A.
Sondergaard, Lars
Teles, Rui C.
Sabaté, Manel
Terkelsen, Christian J.
Testa, Luca
Wu, Jianhua
Maggioni, Aldo P.
Wallentin, Lars
Casadei, Barbara
Gale, Chris P.
Palavras-chave: Aortic valve
Data definitions
Data standards
EuroHeart
Quality of care
Registry
TAVI
Variables
Medicine(all)
SDG 3 - Good Health and Well-being
Data: 7-Ago-2023
Resumo: AIMS: Standardized data definitions are necessary for the quantification of quality of care and patient outcomes in observational studies and randomised controlled trials (RCTs). The European Unified Registries for Heart Care Evaluation and Randomised Trials (EuroHeart) project of the European Society of Cardiology (ESC) aims to create pan-European data standards for cardiovascular diseases and interventions, including transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We followed the EuroHeart methodology for cardiovascular data standard development. A Working Group of 29 members representing 12 countries was established and included a patient representative, as well as experts in the management of valvular heart disease from the European Association of Percutaneous Cardiovascular Interventions (EAPCI), the European Association of Cardiovascular Imaging (EACVI) and the Working Group on Cardiovascular Surgery. We conducted a systematic review of the literature and used a modified Delphi method to reach consensus on a final set of variables. For each variable, the Working Group provided a definition, permissible values, and categorized the variable as mandatory (Level 1) or additional (Level 2) based on its clinical importance and feasibility. In total, 93 Level 1 and 113 Level 2 variables were selected, with the level 1 variables providing the dataset for registration of patients undergoing TAVI on the EuroHeart IT platform. CONCLUSION: This document provides details of the EuroHeart data standards for TAVI processes of care and in-hospital outcomes. In the context of EuroHeart, this will facilitate quality improvement, observational research, registry-based RCTs and post-marketing surveillance of devices, and pharmacotherapies. ONE-SENTENCE SUMMARY: The EuroHeart data standards for transcatheter aortic valve implantation (TAVI) are a set of internationally agreed data variables and definitions that once implemented will facilitate improvement of quality of care and outcomes for patients receiving TAVI.
Descrição: Publisher Copyright: © The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology.
Peer review: yes
URI: http://hdl.handle.net/10362/157010
DOI: https://doi.org/10.1093/ehjqcco/qcac063
ISSN: 2058-5225
Aparece nas colecções:NMS - Artigos em revista internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
qcac063_1_.pdf507,79 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.