Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/155109
Registo completo
Campo DCValorIdioma
dc.contributor.authorAmaral, Tito G.-
dc.contributor.authorPires, Vítor Fernão-
dc.contributor.authorCordeiro, Armando-
dc.contributor.authorFoito, Daniel-
dc.contributor.authorMartins, João F.-
dc.contributor.authorYamnenko, Julia-
dc.contributor.authorTereschenko, Tetyana-
dc.contributor.authorLaikova, Liudmyla-
dc.contributor.authorFedin, Ihor-
dc.date.accessioned2023-07-11T22:22:42Z-
dc.date.available2023-07-11T22:22:42Z-
dc.date.issued2023-03-13-
dc.identifier.issn1996-1073-
dc.identifier.otherPURE: 65888358-
dc.identifier.otherPURE UUID: c4291f72-1d83-42c4-9e5f-67f7ee41896c-
dc.identifier.otherScopus: 85152042996-
dc.identifier.otherWOS: 000957929800001-
dc.identifier.urihttp://hdl.handle.net/10362/155109-
dc.descriptionPublisher Copyright: © 2023 by the authors.-
dc.description.abstractThis article deals with fault detection and the classification of incipient and intermittent open-transistor faults in grid-connected three-level T-type inverters. Normally, open-transistor detection algorithms are developed for permanent faults. Nevertheless, the difficulty to detect incipient and intermittent faults is much greater, and appropriate methods are required. This requirement is due to the fact that over time, its repetition may lead to permanent failures that may lead to irreversible degradation. Therefore, the early detection of these failures is very important to ensure the reliability of the system and avoid unscheduled stops. For diagnosing these incipient and intermittent faults, a novel method based on a Walsh transform combined with a multilayer perceptron (MLP)-based classifier is proposed in this paper. This non-classical approach of using the Walsh transform not only allows accurate detections but is also very fast. This last characteristic is very important in these applications due to their practical implementation. The proposed method includes two main steps. First, the acquired AC currents are used by the control system and processed using the Walsh transform. This results in detailed information used to potentially identify open-transistor faults. Then, such information is processed using the MLP to finally determine whether a fault is present or not. Several experiments are conducted with different types of incipient transistor faults to create a relevant dataset.en
dc.format.extent18-
dc.language.isoeng-
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F50021%2F2020/PT-
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F00066%2F2020/PT-
dc.rightsopenAccess-
dc.subjectartificial neural networks (ANNs)-
dc.subjectfault diagnosis-
dc.subjectincipient and intermittent fault-
dc.subjectmultilevel T-type inverter-
dc.subjectopen transistor-
dc.subjectWalsh transform-
dc.subjectRenewable Energy, Sustainability and the Environment-
dc.subjectFuel Technology-
dc.subjectEngineering (miscellaneous)-
dc.subjectEnergy Engineering and Power Technology-
dc.subjectEnergy (miscellaneous)-
dc.subjectControl and Optimization-
dc.subjectElectrical and Electronic Engineering-
dc.subjectSDG 7 - Affordable and Clean Energy-
dc.titleIncipient Fault Diagnosis of a Grid-Connected T-Type Multilevel Inverter Using Multilayer Perceptron and Walsh Transform-
dc.typearticle-
degois.publication.issue6-
degois.publication.titleEnergies-
degois.publication.volume16-
dc.peerreviewedyes-
dc.identifier.doihttps://doi.org/10.3390/en16062668-
dc.description.versionpublishersversion-
dc.description.versionpublished-
dc.contributor.institutionUNINOVA-Instituto de Desenvolvimento de Novas Tecnologias-
dc.contributor.institutionCTS - Centro de Tecnologia e Sistemas-
dc.contributor.institutionDEE - Departamento de Engenharia Electrotécnica e de Computadores-
Aparece nas colecções:Home collection (FCT)

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Incipient_Fault_Diagnosis_of_a_Grid_Connected_T_Type.pdf2,68 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.