Utilize este identificador para referenciar este registo:
http://hdl.handle.net/10362/144422
Título: | Fault-Tolerant Multilevel Converter to Feed a Switched Reluctance Machine |
Autor: | Pires, Vítor Fernão Cordeiro, Armando Foito, Daniel Pires, Armando J. |
Palavras-chave: | Fault detection Fault diagnosis Fault-tolerant operation Multilevel topology Switched reluctance machine (SRM) Control and Systems Engineering Computer Science (miscellaneous) Mechanical Engineering Control and Optimization Industrial and Manufacturing Engineering Electrical and Electronic Engineering |
Data: | 4-Jan-2022 |
Citação: | Pires, V. F., Cordeiro, A., Foito, D., & Pires, A. J. (2022). Fault-Tolerant Multilevel Converter to Feed a Switched Reluctance Machine. Machines, 10(1), Article 35. https://doi.org/10.3390/machines10010035 |
Resumo: | The switched reluctance machine (SRM) is one of the most interesting machines, being adopted for many applications. However, this machine requires a power electronic converter that usually is the most fragile element of the system. Thus, in order to ensure high reliability for this system, it is fundamental to design a power electronic converter with fault-tolerant capability. In this context, a new solution is proposed to give this capability to the system. This converter was designed with the purpose to ensure fault-tolerant capability to two types of switch faults, namely open-and short-circuit. Moreover, apart from this feature, the proposed topology is characterized by a multilevel operation that allows improvement of the performance of the SRM, taking into consideration a wide speed range. Although the proposed solution is presented for an 8/6 SRM, it can be used for other configurations. The operation of the proposed topology will be described for the two modes, fault-tolerant and normal operation. Another aspect that is addressed in this paper is the proposal of fault detection and diagnosis method for this fault-tolerant inverter. It was specifically developed for a multilevel SRM drive. The theoretical assumptions will be verified through two different types of tests, firstly by simulation and secondly by experiments with a laboratory prototype. |
Descrição: | Funding Information: Funding: This research was funded by FCT Funda?ão para a Ciência e a Tecnologia grant number UID/CEC/50021/2020 and UID/EEA/00066/2020. Publisher Copyright: © 2022 by the authors. Licensee MDPI, Basel, Switzerland. |
Peer review: | yes |
URI: | http://hdl.handle.net/10362/144422 |
DOI: | https://doi.org/10.3390/machines10010035 |
Aparece nas colecções: | Home collection (FCT) |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Fault_Tolerant_Multilevel_Converter_to_Feed_a_Switched.pdf | 6,04 MB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.