Utilize este identificador para referenciar este registo:
http://hdl.handle.net/10362/122436| Título: | Ação antimicrobiana do gás ozônio em superfícies e na aeromicrobiota |
| Outros títulos: | Antimicrobial action of ozone gas on surfaces and in the air |
| Autor: | Caetano, Maicon Henrique Zen Siqueira, João Paulo De Andrade, Denise De Sousa, Álvaro Francisco Lopes Rigotti, Marcelo Alessandro Diniz, Maiara Oliveira De Almeida, Willian Albuquerque Ferreira, Adriano Menis De Almeida, Margarete Teresa Gottardo |
| Palavras-chave: | Air pollution Anti-infective agents Disinfection Indoor Ozonation Ozone Products with antimicrobial action Chemical Health and Safety Inorganic Chemistry Biochemistry, Genetics and Molecular Biology (miscellaneous) Epidemiology Infectious Diseases Public Health, Environmental and Occupational Health Safety, Risk, Reliability and Quality Medical Laboratory Technology Microbiology Parasitology Virology Toxicology Safety Research Environmental Chemistry Health, Toxicology and Mutagenesis Pollution SDG 3 - Good Health and Well-being SDG 6 - Clean Water and Sanitation SDG 8 - Decent Work and Economic Growth SDG 9 - Industry, Innovation, and Infrastructure SDG 12 - Responsible Consumption and Production |
| Data: | 8-Abr-2021 |
| Resumo: | Objetivo: Avaliar a ação antimicrobiano do gás ozônio (O3) em superfícies e ar ambiente climatizado artificialmente. Métodos: Estudo experimental/laboratorial e transversal realizado em dez salas de um laboratório de pesquisa em microbiologia médica, com risco de segurança biológica classe 2. As superfícies demarcadas do chão, parede e bancada foram avaliadas, quanto à presença ou ausência de micro-organismos, a partir de coletas feitas com swab umedecido em água destilada estéril, antes e após a exposição do gás O3 gerado por dois equipamentos distintos. Após este procedimento, o swab foi inoculado na superfície do meio de cultura Brain Heart Infusion Agar DIFCO® (BHI), seguindo-se a incubação a 35ºC por 24 horas. Para a análise microbiológica do ar, uma placa com BHI foi exposta aberta por uma hora, antes e após o tratamento do gás O3, sendo incubadas segundo os mesmos critérios. Resultados: A atividade antimicrobiana do gás O3 gerado por ambos os equipamentos foi constatada para todas as áreas investigadas, com registros de redução do número de Unidades Formadoras de Colônias. O potencial de inibição antimicrobiana dos aparelhos se manteve próximo para os critérios de análise adotados, com destaque para as áreas de chão e bancada. Considerando-se todas as salas e percentuais de inibição microbiana, frente aos dois equipamentos, os resultados foram: chão (100%), bancada (90%), parede (50%) e ar, 70%. Conclusão: Os equipamentos geradores de gás O3 apresentaram potencial antimicrobiano para medida de controle de microrganismos presentes em superfícies e ar ambiente climatizado artificialmente, sendo um sanitizante factível para utilização. Objective: Assess the antimicrobial action of ozone gas (O3) on surfaces and artificially cooled ambient air. Methods: Cross-sectional experimental/laboratory study carried out in ten rooms of a medical microbiology research lab, with class 2 biosafety risk. The demarcated surfaces on the floor, wall and counter were assessed in relation to the presence or absence of microorganisms, based on collections done with swabs dampened in sterile distilled water, before and after exposure to ozone gas produced by two different generators. After this procedure, each swab was inoculated on the surface of a Brain Heart Infusion Agar DIFCO® (BHI) culture, followed by incubation at 35ºC for 24 hours. For the microbiological analysis of the air, a petri dish with BHI was openly exposed for one hour, before and after treatment with O3 gas, and were incubated according to the same criteria. Results: The antimicrobial activity of the O3 gas produced by both generators was checked in all the areas investigated, with records indicating a decrease in the number of colony-forming units. The antimicrobial inhibition potential of the generators was close to the analysis criteria adopted, particularly for the floor and counter areas. Based on all the rooms and microbial inhibition percentages, in relation to the two generators, the results were: floor (100%), counter (90%), wall (50%) and air (70%). Conclusion: The O3 generators had antimicrobial potential as a procedure for controlling microorganisms present on surfaces and in artificially cooled ambient air, constituting a feasible sanitizer. |
| Descrição: | Funding Information: This study was carried out with support from the Federal University of Mato Grosso do Sul (UFMS/MEC–Brazil) and the Coordination for the Improvement of Higher Education Personnel (CAPES) – Financing Code 001. Publisher Copyright: © 2021 Departamento de Enfermagem/Universidade Federal de Sao Paulo. All rights reserved. |
| Peer review: | yes |
| URI: | http://hdl.handle.net/10362/122436 |
| DOI: | https://doi.org/10.37689/ACTA-APE/2021AO02712 |
| ISSN: | 0103-2100 |
| Aparece nas colecções: | IHMT: SPIB - Artigos em revista internacional com arbitragem científica |
Ficheiros deste registo:
| Ficheiro | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| A_o_antimicrobiana_do_g_s_oz_nio_em_superf_cies_e_na_aeromicrobiota.pdf | 1,16 MB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.