Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/122436
Título: Ação antimicrobiana do gás ozônio em superfícies e na aeromicrobiota
Outros títulos: Antimicrobial action of ozone gas on surfaces and in the air
Autor: Caetano, Maicon Henrique
Zen Siqueira, João Paulo
De Andrade, Denise
De Sousa, Álvaro Francisco Lopes
Rigotti, Marcelo Alessandro
Diniz, Maiara Oliveira
De Almeida, Willian Albuquerque
Ferreira, Adriano Menis
De Almeida, Margarete Teresa Gottardo
Palavras-chave: Air pollution
Anti-infective agents
Disinfection
Indoor
Ozonation
Ozone
Products with antimicrobial action
Chemical Health and Safety
Inorganic Chemistry
Biochemistry, Genetics and Molecular Biology (miscellaneous)
Epidemiology
Infectious Diseases
Public Health, Environmental and Occupational Health
Safety, Risk, Reliability and Quality
Medical Laboratory Technology
Microbiology
Parasitology
Virology
Toxicology
Safety Research
Environmental Chemistry
Health, Toxicology and Mutagenesis
Pollution
SDG 3 - Good Health and Well-being
SDG 6 - Clean Water and Sanitation
SDG 8 - Decent Work and Economic Growth
SDG 9 - Industry, Innovation, and Infrastructure
SDG 12 - Responsible Consumption and Production
Data: 8-Abr-2021
Resumo: Objetivo: Avaliar a ação antimicrobiano do gás ozônio (O3) em superfícies e ar ambiente climatizado artificialmente. Métodos: Estudo experimental/laboratorial e transversal realizado em dez salas de um laboratório de pesquisa em microbiologia médica, com risco de segurança biológica classe 2. As superfícies demarcadas do chão, parede e bancada foram avaliadas, quanto à presença ou ausência de micro-organismos, a partir de coletas feitas com swab umedecido em água destilada estéril, antes e após a exposição do gás O3 gerado por dois equipamentos distintos. Após este procedimento, o swab foi inoculado na superfície do meio de cultura Brain Heart Infusion Agar DIFCO® (BHI), seguindo-se a incubação a 35ºC por 24 horas. Para a análise microbiológica do ar, uma placa com BHI foi exposta aberta por uma hora, antes e após o tratamento do gás O3, sendo incubadas segundo os mesmos critérios. Resultados: A atividade antimicrobiana do gás O3 gerado por ambos os equipamentos foi constatada para todas as áreas investigadas, com registros de redução do número de Unidades Formadoras de Colônias. O potencial de inibição antimicrobiana dos aparelhos se manteve próximo para os critérios de análise adotados, com destaque para as áreas de chão e bancada. Considerando-se todas as salas e percentuais de inibição microbiana, frente aos dois equipamentos, os resultados foram: chão (100%), bancada (90%), parede (50%) e ar, 70%. Conclusão: Os equipamentos geradores de gás O3 apresentaram potencial antimicrobiano para medida de controle de microrganismos presentes em superfícies e ar ambiente climatizado artificialmente, sendo um sanitizante factível para utilização. Objective: Assess the antimicrobial action of ozone gas (O3) on surfaces and artificially cooled ambient air. Methods: Cross-sectional experimental/laboratory study carried out in ten rooms of a medical microbiology research lab, with class 2 biosafety risk. The demarcated surfaces on the floor, wall and counter were assessed in relation to the presence or absence of microorganisms, based on collections done with swabs dampened in sterile distilled water, before and after exposure to ozone gas produced by two different generators. After this procedure, each swab was inoculated on the surface of a Brain Heart Infusion Agar DIFCO® (BHI) culture, followed by incubation at 35ºC for 24 hours. For the microbiological analysis of the air, a petri dish with BHI was openly exposed for one hour, before and after treatment with O3 gas, and were incubated according to the same criteria. Results: The antimicrobial activity of the O3 gas produced by both generators was checked in all the areas investigated, with records indicating a decrease in the number of colony-forming units. The antimicrobial inhibition potential of the generators was close to the analysis criteria adopted, particularly for the floor and counter areas. Based on all the rooms and microbial inhibition percentages, in relation to the two generators, the results were: floor (100%), counter (90%), wall (50%) and air (70%). Conclusion: The O3 generators had antimicrobial potential as a procedure for controlling microorganisms present on surfaces and in artificially cooled ambient air, constituting a feasible sanitizer.
Descrição: Funding Information: This study was carried out with support from the Federal University of Mato Grosso do Sul (UFMS/MEC–Brazil) and the Coordination for the Improvement of Higher Education Personnel (CAPES) – Financing Code 001. Publisher Copyright: © 2021 Departamento de Enfermagem/Universidade Federal de Sao Paulo. All rights reserved.
Peer review: yes
URI: http://hdl.handle.net/10362/122436
DOI: https://doi.org/10.37689/ACTA-APE/2021AO02712
ISSN: 0103-2100
Aparece nas colecções:IHMT: SPIB - Artigos em revista internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
A_o_antimicrobiana_do_g_s_oz_nio_em_superf_cies_e_na_aeromicrobiota.pdf1,16 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.