Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/117176
Título: Fluorometric determination of ethidium bromide efflux kinetics in Escherichia coli.
Autor: Paixão, Laura
Rodrigues, L
Couto, Isabel Maria dos Santos Leitão
Martins, Marta
Fernandes, Pedro
de Carvalho, Carla CCR
Monteiro, Gabriel A
Sansonetty, Filipe
Amaral, Leonard
Viveiros, M
Palavras-chave: Biochemistry, Genetics and Molecular Biology (miscellaneous)
Microbiology
Infectious Diseases
SDG 3 - Good Health and Well-being
Data: 1-Jan-2009
Resumo: BACKGROUND Efflux pump activity has been associated with multidrug resistance phenotypes in bacteria, compromising the effectiveness of antimicrobial therapy. The development of methods for the early detection and quantification of drug transport across the bacterial cell wall is a tool essential to understand and overcome this type of drug resistance mechanism. This approach was developed to study the transport of the efflux pump substrate ethidium bromide (EtBr) across the cell envelope of Escherichia coli K-12 and derivatives, differing in the expression of their efflux systems. RESULTS EtBr transport across the cell envelope of E. coli K-12 and derivatives was analysed by a semi-automated fluorometric method. Accumulation and efflux of EtBr was studied under limiting energy supply (absence of glucose and low temperature) and in the presence and absence of the efflux pump inhibitor, chlorpromazine. The bulk fluorescence variations were also observed by single-cell flow cytometry analysis, revealing that once inside the cells, leakage of EtBr does not occur and that efflux is mediated by active transport. The importance of AcrAB-TolC, the main efflux system of E. coli, in the extrusion of EtBr was evidenced by comparing strains with different levels of AcrAB expression. An experimental model was developed to describe the transport kinetics in the three strains. The model integrates passive entry (influx) and active efflux of EtBr, and discriminates different degrees of efflux between the studied strains that vary in the activity of their efflux systems, as evident from the calculated efflux rates: = 0.0173 +/- 0.0057 min-1; = 0.0106 +/- 0.0033 min-1; and = 0.0230 +/- 0.0075 min-1. CONCLUSION The combined use of a semi-automated fluorometric method and an experimental model allowed quantifying EtBr transport in E. coli strains that differ in their overall efflux activity. This methodology can be used for the early detection of differences in the drug efflux capacity in bacteria accounting for antibiotic resistance, as well as for expedite screening of new drug efflux inhibitors libraries and transport studies across the bacterial cell wall.
Peer review: yes
URI: http://hdl.handle.net/10362/117176
DOI: https://doi.org/10.1186/1754-1611-3-18
Aparece nas colecções:IHMT: MM - Artigos em revista internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Fluorometric_determination_of_ethidium_bromide_efflux_kinetics.pdf524,56 kBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.