Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/114330
Registo completo
Campo DCValorIdioma
dc.contributor.authorMachado, Jorge-
dc.contributor.authorCarvalho, Patrícia M. S.-
dc.contributor.authorFélix, Ana-
dc.contributor.authorDoutel, Delfin-
dc.contributor.authorSantos, José Paulo-
dc.contributor.authorCarvalho, Maria Luísa-
dc.contributor.authorPessanha, Sofia-
dc.date.accessioned2021-03-23T23:26:32Z-
dc.date.available2022-03-31T00:31:41Z-
dc.date.issued2020-12-
dc.identifier.issn0267-9477-
dc.identifier.otherPURE: 27916504-
dc.identifier.otherPURE UUID: 2add2220-ccfc-4397-89c9-ae0a4f996245-
dc.identifier.otherScopus: 85099026879-
dc.identifier.otherWOS: 000596707400013-
dc.identifier.otherORCID: /0000-0002-5890-0971/work/88881417-
dc.identifier.otherORCID: /0000-0002-2653-2262/work/88881499-
dc.identifier.otherORCID: /0000-0002-6039-2494/work/88882845-
dc.identifier.urihttp://hdl.handle.net/10362/114330-
dc.descriptionUID/FIS/04559/2019 to LIBPhys-UNL from the FCT/MCTES/PIDDAC, Portugal. FCT contract No. PD/BD/128324/2017.-
dc.description.abstractIn this work, we aim at achieving the most accurate quantitative determination of elements in human tissues by means of X-ray Fluorescence spectrometry using the external calibration approach. A calibration curve built using a set of certified reference materials (CRM) of animal tissue was compared with the one obtained with a set of CRMs of plants and leaves with lower atomic number Z but with correction of the matrix using the scattering peaks of the X-ray tube anode. Finally, a calibration curve combining the two sets of CRMs was built and the accuracy of the quantification using the three methods was compared and a more precise method of quantification was obtained. This improved approach was tested on five paired samples of normal and tumour human tissue. Despite the high heterogeneity of the samples, and given the improvement in accuracy of the measurements, significant differences were found in the elemental concentration of low-Z elements. This journal isen
dc.format.extent8-
dc.language.isoeng-
dc.rightsopenAccesspt_PT
dc.subjectAnalytical Chemistry-
dc.subjectSpectroscopy-
dc.titleAccuracy improvement in XRF analysis for the quantification of elements ranging from tenths to thousands μg g-1in human tissues using different matrix reference materials-
dc.typearticle-
degois.publication.firstPage2920-
degois.publication.issue12-
degois.publication.lastPage2927-
degois.publication.titleJournal of Analytical Atomic Spectrometry-
degois.publication.volume35-
dc.peerreviewedyes-
dc.identifier.doihttps://doi.org/10.1039/d0ja00307g-
dc.description.versionauthorsversion-
dc.description.versionpublished-
dc.contributor.institutionLIBPhys-UNL-
dc.contributor.institutionDF – Departamento de Física-
dc.contributor.institutionNOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)-
dc.contributor.institutionCentro de Estudos de Doenças Crónicas (CEDOC)-
Aparece nas colecções:NMS: CEDOC - Artigos em revista internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
JA_ART_07_2020_000307.R2_Proof_hi.pdf2,67 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.