Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/106279
Registo completo
Campo DCValorIdioma
dc.contributor.authorMartins, Carla F.-
dc.contributor.authorNeves, Luísa A.-
dc.contributor.authorChagas, Ricardo-
dc.contributor.authorFerreira, Luísa M.-
dc.contributor.authorAfonso, Carlos M.-
dc.contributor.authorCrespo, João G.-
dc.contributor.authorCoelhoso, Isabel M.-
dc.date.accessioned2020-10-28T00:06:01Z-
dc.date.available2022-11-02T01:33:59Z-
dc.date.issued2020-11-01-
dc.identifier.citationMartins, C. F., Neves, L. A., Chagas, R., Ferreira, L. M., Afonso, C. M., Crespo, J. G., & Coelhoso, I. M. (2020). CO2 removal from anaesthesia circuits using gas-ionic liquid membrane contactors. Separation and Purification Technology, 250, Article 116983. https://doi.org/10.1016/j.seppur.2020.116983-
dc.identifier.issn1383-5866-
dc.identifier.otherPURE: 18761637-
dc.identifier.otherPURE UUID: 083430a7-c155-490c-b3e2-4c9474bd32a1-
dc.identifier.otherScopus: 85086435796-
dc.identifier.otherWOS: 000552061600007-
dc.identifier.otherORCID: /0000-0001-8474-3925/work/82362716-
dc.identifier.otherORCID: /0000-0002-9620-6286/work/82363235-
dc.identifier.otherORCID: /0000-0001-8714-3781/work/82363424-
dc.identifier.otherORCID: /0000-0001-7032-3436/work/82363440-
dc.identifier.urihttp://hdl.handle.net/10362/106279-
dc.descriptionUIDB/50006/2020 SFRH/BD/111128/2015 IF/00505/2014/CP1224/CT0004-
dc.description.abstractNowadays, the reutilization of anaesthetic gases is accomplished by capturing carbon dioxide with soda lime, a solid adsorbent mostly composed by calcium and sodium hydroxide. To overcome the issues regarding the use of soda lime, this work proposes an alternative process to remove carbon dioxide through the use of a membrane contactor combined with a biocompatible ionic liquid (IL), cholinium lysinate, with high absorption capacity (5.9 molCO2/kgIL). The carbon dioxide removal rate and IL solution regeneration, were assessed, varying the feed gas composition, relative humidity and ionic liquid flow rate conditions. Overall mass transfer coefficients and separation factors were determined. From the results obtained, the proposed system is feasible to remove carbon dioxide from anaesthetic gas circuits. Moreover, the system working operation time obtained was 63 h, which in a mass basis comparison with soda lime (current technology), is 3–5 times higher.en
dc.language.isoeng-
dc.rightsopenAccesspt_PT
dc.subjectAnaesthetic gas-
dc.subjectBiocompatible ionic liquid-
dc.subjectCO removal-
dc.subjectGas-liquid membrane contactor-
dc.subjectAnalytical Chemistry-
dc.subjectFiltration and Separation-
dc.titleCO2 removal from anaesthesia circuits using gas-ionic liquid membrane contactors-
dc.typearticle-
degois.publication.titleSeparation and Purification Technology-
degois.publication.volume250-
dc.peerreviewedyes-
dc.identifier.doihttps://doi.org/10.1016/j.seppur.2020.116983-
dc.description.versionproof-
dc.description.versionpublished-
dc.contributor.institutionDQ - Departamento de Química-
dc.contributor.institutionLAQV@REQUIMTE-
dc.contributor.institutionCENIMAT-i3N - Centro de Investigação de Materiais (Lab. Associado I3N)-
dc.contributor.institutionDCM - Departamento de Ciência dos Materiais-
Aparece nas colecções:FCT: DQ - Artigos em revista internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
1_s2.0_S138358662031457X_main.pdf1,18 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.