Utilize este identificador para referenciar este registo:
http://hdl.handle.net/10362/105971
Título: | Development of an experimental setup for microflow measurement using interferometry |
Autor: | Batista, Elsa Godinho, Isabel Martins, Rui F. Mendes, Ricardo Robarts, João |
Palavras-chave: | Calibration Interferometry Measurement uncertainty Microflow measurement Modelling and Simulation Instrumentation Computer Science Applications Electrical and Electronic Engineering |
Data: | Out-2020 |
Citação: | Batista, E., Godinho, I., Martins, R. F., Mendes, R., & Robarts, J. (2020). Development of an experimental setup for microflow measurement using interferometry. Flow Measurement and Instrumentation, 75, Article 101789. https://doi.org/10.1016/j.flowmeasinst.2020.101789 |
Resumo: | The precise measurement of micro and nanoflow of incompressible liquids (below 1 μL/h) is a complex task due to several factors involved in, namely, evaporation, adsorption and the existence of air bubbles within the system. Nevertheless, the importance of its measurement is undeniable in equipment such as insulin pumps, or medical drug delivery devices for new-born, microchip flow pumps, to mention few. The work herein presented was developed in a partnership between the Volume and Flow Laboratory (LVC) of the Portuguese Institute of Quality (IPQ) and the Department of Mechanical and Industrial Engineering (DEMI) of The New University of Lisbon under the project MeDD II – Metrology for Drug Delivery. It had the main objective of conceiving a new Portuguese standard for the measurement of ultra-low flow using interferometry, with a target uncertainty of 1% (k = 2). Therefore, the new setup relies on an interferometer made up of a laser unit, two retroreflector cubes, one beam splitter, as well as a flow generator (a Nexus syringe pump) and a computer for data acquisition. Experimental tests on a Flow generator and a Coriolis flow meter were carried out at different flow rates. With the innovative methodology developed during the present research, it was possible to measure flow rates of an incompressible fluid (water) down to 1 μL/h with an uncertainty of 3% (k = 2). |
Descrição: | This work performed under MeDDII project has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme. |
Peer review: | yes |
URI: | http://hdl.handle.net/10362/105971 |
DOI: | https://doi.org/10.1016/j.flowmeasinst.2020.101789 |
ISSN: | 0955-5986 |
Aparece nas colecções: | FCT: UNIDEMI - Artigos em revista internacional com arbitragem científica |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
1_s2.0_S0955598620301345_main.pdf | 3,89 MB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.