Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/105312
Título: An uncertainties simulation model applied to an automated laminar flowmeter
Autor: Pedro, António
Morgado, Teresa
Navas, Helena
Palavras-chave: Air data test set
Aircraft oxygen system
Automated laminar flowmeter
Calibration
Monte Carlo method
Test bench
Uncertainty
Materials Science(all)
Instrumentation
Engineering(all)
Process Chemistry and Technology
Computer Science Applications
Fluid Flow and Transfer Processes
Data: 1-Fev-2020
Citação: Pedro, A., Morgado, T., & Navas, H. (2020). An uncertainties simulation model applied to an automated laminar flowmeter. Applied Sciences, 10(3), Article 888. https://doi.org/10.3390/app10030888
Resumo: Aircraft oxygen regulators are a normally used specialized test bench designed to perform tests to the regulators during its work conditions. The tests are performed placing the regulator in the barometric chamber, where low pressure conditions are forced to simulate altitude conditions and then a flow is forced on the output of the regulator to simulate the inhalation of the user. The relevant test flows are measured by laminar flowmeters. These flowmeters are meant to measure the flowrate at pressures correspondent to altitudes between sea level altitude and fifty thousand feet. In this work a way was studied to automate laminar flowmeters used on oxygen regulator test benches. For this purpose, was developed a data acquisition system (DAS) using a microcontroller board and two microelectromechanical systems-MEMSs (a pressure and temperature sensor and a differential pressure sensor). Since these MEMSs did not have factory calibration, they were calibrated in this study. The automated flowmeter was also calibrated. To estimate the error of flow rate measured by this solution, an uncertainties simulation model based on the Monte Carlo method and several calibrations were performed. According to the automated flowmeter calibration, the uncertainty obtained (0.45% fs) is accepted, but the authors only recommend its use for actual volumetric flowrate measurements.
Peer review: yes
URI: http://hdl.handle.net/10362/105312
DOI: https://doi.org/10.3390/app10030888
ISSN: 2076-3417
Aparece nas colecções:FCT: DEMI - Artigos em revista internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
applsci_10_00888_v2.pdf1,37 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.