Logo do repositório
 
Publicação

Personalized mechanical ventilation guided by lung ultrasound in patients with ARDS

dc.contributor.authorSinnige, Jante S.
dc.contributor.authorSmit, Marry R.
dc.contributor.authorAlam, Mohammad J.
dc.contributor.authorChowdhury, Mohammed N.H.
dc.contributor.authorCosta, Vasco
dc.contributor.authorde Castro, Heloísa S.M.B.
dc.contributor.authorDaszuta, Dominik
dc.contributor.authorFilippini, Daan F.L.
dc.contributor.authorGhose, Aniruddha
dc.contributor.authorde Grooth, Harm Jan
dc.contributor.authorHein, Lars
dc.contributor.authorHermans, Greet
dc.contributor.authorHildebrandt, Thomas
dc.contributor.authorItenov, Theis Skovsgaard
dc.contributor.authorIschaki, Eleni
dc.contributor.authorKlompmaker, Peter
dc.contributor.authorLaffey, John
dc.contributor.authorMcMahon, Aisling
dc.contributor.authorMcNicholas, Bairbre
dc.contributor.authorMousa, Amne
dc.contributor.authorPaulus, Frederique
dc.contributor.authorPedersen, Ulf Gøttrup
dc.contributor.authorPellegrini, Mariangela
dc.contributor.authorPezzuto, Marco
dc.contributor.authorPóvoa, Pedro
dc.contributor.authorPierrakos, Charalampos
dc.contributor.authorPisani, Luigi
dc.contributor.authorRoca, Oriol
dc.contributor.authorSchultz, Marcus J.
dc.contributor.authorSpadaro, Savino
dc.contributor.authorSzuldrzynski, Konstanty
dc.contributor.authorTheodorou, Evangelia
dc.contributor.authorTuinman, Pieter R.
dc.contributor.authorWamberg, Christian A.
dc.contributor.authorZimatore, Claudio
dc.contributor.authorBos, Lieuwe D.J.
dc.contributor.authorAhmed, Arif Uddin
dc.contributor.authorBarua, Samarjit
dc.contributor.authorNowroz, Nahid
dc.contributor.authorHassan, Nahid
dc.contributor.authorVaporidi, Katerina
dc.contributor.authorSiempos, Ilias
dc.contributor.authorKanavou, Angeliki
dc.contributor.authorGiannopoulos, Harry
dc.contributor.authorKawati, Rafael
dc.contributor.authorBjarnadottir, Kristin Jona
dc.contributor.authorMason, Sabina
dc.contributor.authorKelly, Yvelynne
dc.contributor.authorNora, David
dc.contributor.authorBergin, Paul
dc.contributor.institutionNOVA Medical School|Faculdade de Ciências Médicas (NMS|FCM)
dc.contributor.institutionComprehensive Health Research Centre (CHRC) - pólo NMS
dc.contributor.pblEuropean Society of Intensive Care Medicine (ESICM) | SpringerOpen
dc.date.accessioned2026-01-14T15:58:04Z
dc.date.available2026-01-14T15:58:04Z
dc.date.issued2025-12
dc.descriptionPublisher Copyright: © The Author(s) 2025.
dc.description.abstractBackground: The “Personalized Mechanical Ventilation Guided by Lung UltraSound in Patients with Acute Respiratory Distress Syndrome” (PEGASUS) study aims to evaluate personalized mechanical ventilation (MV) in patients with acute respiratory distress syndrome (ARDS) compared to the standard of care. However, misclassification and misaligned MV strategies were shown to be harmful. We therefore aimed to assess the interobserver agreement of lung ultrasound (LUS) between the local investigator and an expert panel in classifying ARDS subphenotypes alongside protocol adherence and safety endpoints, as a pilot phase of the ongoing PEGASUS study. Methods: The first 80 mechanically ventilated patients with moderate-to-severe ARDS were enrolled in the ongoing PEGASUS study, a randomized clinical trial (RCT), and were included in the pilot phase. Focal or non-focal subphenotypes were classified using a LUS. Positive end-expiratory pressures (PEEP), tidal volumes (VT), the application of recruitment manoeuvres, and proning were performed according to randomization arm and subphenotype. Safety limits for MV followed current guidelines. Agreement in subphenotype classification between local investigators and a panel of three experts was evaluated using Cohen’s κ coefficient. Results: In 68 out of 80 exams, the images were of sufficient quality for assessment. The interobserver agreement for the lung morphology had a Cohen’s kappa of 0.72 (95% CI 0.53–0.9) and accuracy of 88% between local investigator and the expert panel. Misclassification occurred in 8/68 exams (11.8%). Among these 8 misclassified cases, 6 (75%) also showed disagreement between experts due to different LUS scores of the anterior regions. Tidal volume and PEEP were generally set according to the protocol. An exception was the TV in the non-focal ARDS patients randomized to personalized MV, where the median (6.2 ml/kg/PBW) was above the target range (4–6 ml/kg/PBW). Patients exceeding safety limits of MV were low. Conclusion: In the pilot phase of an ongoing international subphenotype-targeted RCT, we found that local investigators’ assessments agreed with expert panel consensus assessments in the large majority of cases, and nearly always when the expert panel assessment was unanimous. Protocol adherence was sufficient, but tidal volume in the non-focal subphenotype deserves attention during continuation of the study. Trial registration: The study was registered on clinicaltrial.gov (ID: NCT05492344, date 2022-08-05).en
dc.description.versionpublishersversion
dc.description.versionpublished
dc.format.extent977045
dc.identifier.doi10.1186/s40635-025-00835-8
dc.identifier.issn2197-425X
dc.identifier.otherPURE: 149350907
dc.identifier.otherPURE UUID: 1e4dd162-27da-4bdb-823b-5305f7bd721f
dc.identifier.otherScopus: 105026675643
dc.identifier.otherWOS: 001643155400001
dc.identifier.urihttp://hdl.handle.net/10362/199113
dc.identifier.urlhttps://www.scopus.com/pages/publications/105026675643
dc.language.isoeng
dc.peerreviewedyes
dc.subjectArtificial respiration
dc.subjectPrecision medicine
dc.subjectRespiratory distress syndrome
dc.subjectUltrasonography
dc.subjectEmergency Medicine
dc.subjectCritical Care and Intensive Care Medicine
dc.subjectPhysiology (medical)
dc.titlePersonalized mechanical ventilation guided by lung ultrasound in patients with ARDSen
dc.title.subtitlea pilot phase of a randomized clinical trialen
dc.typejournal article
degois.publication.issue1
degois.publication.titleIntensive Care Medicine Experimental
degois.publication.volume13
dspace.entity.typePublication
rcaap.rightsopenAccess

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
s40635-025-00835-8.pdf
Tamanho:
954.15 KB
Formato:
Adobe Portable Document Format