Utilize este identificador para referenciar este registo: http://hdl.handle.net/10362/153089
Registo completo
Campo DCValorIdioma
dc.contributor.authorGomes, Gabriel de Jesus-
dc.contributor.authorLúcio, Valter José da Guia-
dc.contributor.authorCismaşiu, Corneliu-
dc.contributor.authorMingote, José Luis-
dc.date.accessioned2023-05-23T22:18:51Z-
dc.date.available2023-05-23T22:18:51Z-
dc.date.issued2023-02-24-
dc.identifier.issn2075-5309-
dc.identifier.otherPURE: 61245506-
dc.identifier.otherPURE UUID: 938aa4ba-d187-4df4-9679-b19466cf26ed-
dc.identifier.otherScopus: 85152683936-
dc.identifier.otherWOS: 000957212300001-
dc.identifier.otherORCID: /0000-0002-5703-8072/work/137737550-
dc.identifier.otherORCID: /0000-0002-5864-551X/work/151390424-
dc.identifier.urihttp://hdl.handle.net/10362/153089-
dc.descriptionPublisher Copyright: © 2023 by the authors.-
dc.description.abstractThe paper presents a full-scale blast testing experimental campaign conducted on an energyabsorbing connector comprising thin-walled inversion tubes as kernel elements mounted in a façade protective panel. LS-DYNA finite element predictions of the global and local deformation/inversion of the panel/connectors compared reasonably well with the experimental observations. After validation, the numerical model was used to analyze the response of a simple idealized reinforced concrete structure under three blast-loading scenarios: the first two scenarios produce, approximately, the same impulse but are significantly different in terms of load duration and overpressures, and represent a far-field and a near-field scenario (1600 kg TNT at 20 m (i) and 150 kg TNT at 5 m (ii), respectively); the third scenario is more demanding, and consists in a half standoff distance of the second (150 kg TNT at 2.5 m (iii)). These numerical simulations allow to assess the effect of standoff distance and blast loading on the effectiveness of the protective system. One may conclude that the introduction of EACs strongly limits the forces imparted to the protected structure, reducing significantly the corresponding energy absorption demand. Comparing the energy absorbed by the structure in different scenarios, with and without the protective system (8 × ϕ64 × 2 mm), one can see that these reductions can reach, respectively 67%, 72% and 68% in the far-field, near-field and very near-field explosions.en
dc.format.extent20-
dc.language.isoeng-
dc.relationinfo:eu-repo/grantAgreement/FCT/3599-PPCDT/PTDC%2FECI-EST%2F31046%2F2017/PT-
dc.rightsopenAccess-
dc.subjectblast mitigation-
dc.subjectblast protection-
dc.subjectblast testing-
dc.subjectenergy-absorbing connectors-
dc.subjectfaçade protective cladding-
dc.subjectfree external inversion-
dc.subjectinverted tubes-
dc.subjectArchitecture-
dc.subjectCivil and Structural Engineering-
dc.subjectBuilding and Construction-
dc.titleExperimental Validation and Numerical Analysis of a High-Performance Blast Energy-Absorbing System for Building Structures-
dc.typearticle-
degois.publication.issue3-
degois.publication.titleBuildings-
degois.publication.volume13-
dc.peerreviewedyes-
dc.identifier.doihttps://doi.org/10.3390/buildings13030601-
dc.description.versionpublishersversion-
dc.description.versionpublished-
dc.contributor.institutionCERIS - Polo NOVA-
dc.contributor.institutionDEC - Departamento de Engenharia Civil-
Aparece nas colecções:FCT: DEC - Artigos em revista internacional com arbitragem científica

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Experimental_Validation_and_Numerical_Analysis.pdf3,86 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.